Attachment of the Electrodes, Cable Connection, Readout of Results // Text // In order to have success with the PcE-Trainer for energy training, brain dominance, performance capability, concentration and personal intuition, use the standard cable (Dual Cable).Plug the connector of the dual cable into its receptable:grab the cable connector such tha... // Biofeedback, Biofeedback Instruments and Biofeedback Training - The IPN
The Homepage of the IPN
(klick here to go to the homepage)

 

Biofeedback Training | Biofeedback Products | Biofeedback | Biofeedback Training | Biokybernetics | Biofeedback Device | Biofeedback Measurement | altenative medical instrument | Biokybernetics | PcE-Trainer | Biofeedback0,3269588 | Biomedizine
to Mainmenu
IPN
Userguide
controls
function
measurement
results
errors
 
Training
Biofeedback
PcE Training
7 Exercises
CHI energy
  Mainmenu  > The PcE-Trainer  >  The complete User Guide
Start with the Measurements
Attachment of the Electrodes, Cable Connection, Readout of Results

In order to have success with the PcE-Trainer for energy training, brain dominance, performance capability, concentration and personal intuition, use the standard cable (Dual Cable).

Plug the connector of the dual cable into its receptable:

  • grab the cable connector such that the screw points down.
  • plug the connector into its receptable, the connection should be smooth and easy.
  • grap the collar, push it forward und turn it to the right until it stops.
  • the whole connection should now be solid.

Put the headband around your head:

  • it should have a slight tension
  • the silvery surface of the electrodes should be towards the skin
  • the electrode surface should touch your skin directly
  • part the hair on the back of your head such that the electrodes can make contact with the skin directly
  • the locking mechanism should be in the back
  • if necessary clean the skin under the electrodes with some alcohol

Snap in the four wire ends of the cable into the connector ends of the electrodes:

  • the longer red wire right front
  • the shorter red wire right back
  • the longer blue wire left front
  • the shorter blue wire left back

Put some gel between the skin and the electrodes
  • slightly lift the headband where each electrode is
  • put one drop of gel in
  • such that the test person should feel the moisture, especially in the back
  • this will ensure a good contact between skin and electrode, necessary for a good measurement

Turn on the instrument with the switch in the back moved towards the position "I".

Now take a reading of the values visible on the LCD-Display.

  • Do not forget to turn off the instrument after use.
  • After each session electrodes and headband should be cleaned thoroughly because of hygene. At the same time you increase the life expectancy. This is best done with some cleaning alcohol.

 

 

Next: Interpret the Measurement Results
 